Features
Villa, hotel, residential security, large base station, office, small manufacturing enterprises, computer centers, industrial automation equipment, network room, IDC data center, banking equipment, securities, health care, transportation, petrochemial and ohter solar systems.
1. High reliability:
- High speed micro-controller DSP digital control technology to archieve real-time control, parameter setting, data detection, self-test funcrion ti ensure high reliable operation of the system.
- With high speed swithing characteristic, high voltage, high current, low internal resistance, low dissipation IGBT, MOSFET power components based, to ensure system security and reliability.
2. N+1 modularized MPPT tracking system:
- Multipath MPPT control system access, independent input, operation. More suitable for roof project, to improve power generation efficiency of the panels.
3. PV proactive power supply function:
After detects PV energy, system will enter MPPT status automatically, and it will also adjust the power distribution, priority in the use of PV energy.
4. Intelligent battery managment system:
- In this system, AC rectifier, MPPT controller controlled by intelligent data exchange and communication system. User can set the battery capacity by themselves: battery configuration can be set by the operator interface. System will automatically adjust the charging current, charging voltage and charging mode.
- In special cases, international technical engineer can adjust the charging rate and battery number according to the system configuration.
5. Plenteous communicational interface:
- RS485, RS232 (standart), SNMP (Option).
- Input dry contact to switch on/off inverter, clear abnormal, EPO remotely. Output dry contacts singles for remoe alarm.
6. Intelligent storage staggering features:
System with intelligent peak load shifting function, the user can set the appropriate time period electricity according to the local electricity policy, to achieve load shifting features directly in order to bring economic value;
Product overview
WF series product use high speed DSP control unit, advanced high speed IGBT, MOSFET components, with pulse width modulation (SVPWM) technique disturbance type MPPT control, and double conversion system configuration. Under high-speed DSP system control, the system can quickly track panels to do high-power, load change and efficient multi-level control system, even if the mains input voltage and frequency suddenly change, over/under voltage, or power disturbances, it also can ensure provide the load with regulated voltage and fraquancy power. System has a reliable, environmentally friendly, high intalligence and other characteristics.
Technical Specifications
Model | WF 60KVA |
Rated Power | 54kW |
Rated Current | 91A |
Output Power factor | 0.9 |
Rated input voltage | 380V ± 20% |
Rated output voltage | 380V ± 1% |
Battery voltage | 360Vdc |
Battery quantity/cell | 30/180 |
Working mode | PV, AC replenish |
PV input | |
Max. voltage range (Voc) | 0Vdc-750Vdc |
Best working voltage (Vmp) | 444Vdc-550Vdc |
Float charging voltage | 428V ± 1% |
Max efficiency | ≥98% |
Equalize charging voltage | 414V ± 1% |
Max current | 180A |
PV input ways | 1+1 (reserved) |
MPPT modular | 1+1 (reserved) |
AC rectifier | |
Input voltage range | Three phases 380V ± 20% (-10% ̴ +20% can charge battery) |
Rated frequency | 50Hz / 60Hz (can be set backstage) |
Frequency range | 50Hz / 60Hz ± 5Hz |
Soft start | 0 – 100% 10s |
Power factor | 0.8 |
Float charging voltage (20⁰C) | 410V ± 1% |
Max. voltage | 415V ± 1% |
Max. charging current (A)
Battery capacity allowed |
75 |
Inverter | |
Rated current (A) | 91 |
Inverter voltage | Three phases four lines +G 380 Vac |
Phase voltage setting | 220-230-240 Vac (can be set backstage) |
Output voltage accurancy | ± 1% |
Voltage transient range | ± 5% |
Transient recovery time | 20 ms |
Rated frequency | 50Hz / 60Hz ± 1% |
Frequency tracking range | 50Hz / 60Hz ± 3Hz |
Crest factor | 3 : 1 |
Wave | Pure sine wave |
THD | ≤ 3% (linear load) |
Voltage unbalance degree | ± 3% (100% unbalanced load) |
Overload | ≥ 105% – 110%: transfer to bypass 1 hours later, recover when reduce load; ≥ 110% – 125%: transfer to bypass 10 min later, recover when reduce load; ≥ 125% – 150%: transfer to bypass 1 min later, recover when reduce load; ≥ 150%: transfer to bypass 10 s later, recover when user confirmed; ≥ 200%: shutdown immediately, recover when user confirmed; |
Short circuit | System current limited, shutdown immediately, boot by user |
Max efficiency | ≥ 93% |
Bypass | |
Rated voltage | Three phases four lines +G 380 Vac |
Voltage range | ± 20% |
Rated frequency | 50Hz / 60Hz ± 5Hz |
Max current | 114 A |
Battery Management | |
End of discharge | 315VDC |
Charging current setting | Factory settings is 0.15C; user can set 0.05 – 0.3C |
Battery Intelligent Management | Equalizing charging and float charging automatically transfer; automatic temperature compensation for battery (when battery detection not connected, default environment temperature) |
Staggering depth of discharge settings | 1.85V – 2.1V : can be set by user |
Transfer time | |
Inverter/ bypass transfer time | 0 ms |
Communication interface | |
Remote control input | Inverter on, off, abnormal clear, emergency power off |
PC monitoring interface | RS232, RS485, SNMP (optional) |
Dry Contact | Bypass input abnormal, rectifier input abnormal, system fault, system warning, low battery, overload, fans fault, generator ON/OFF |
Environment | |
Operation temperature | 0-42⁰C |
Max. relative Humidity | 90% noncondenced |
Max. working Altitude | 1000m (100 m higher, 1% derated; max 4000m) |
Other | |
Cooling way | Forced ventilation (Fans speed varies with load) |
Noise (varies with load and temperature) dB | 60 |
Mean time between failures (MTBF) | 200.000 hours |
Defend grade | IP20 |
Power line input | Below |
Standard | IEC62040-1-1, EN62109-1:2010, EN62109-2:2011 |
Dimensions (W*D*H) mm | 600*700*1750 |
Packing dimensions (W*D*H) mm | 690*790*1850 |
Weight | 360 |